Rectification and repair of a faulty air conditioner – mechanical engineering project topics – complete project topic

 

Table Of Contents


Chapter ONE

INTRODUCTION

  • 1.1Introduction
  • 1.2Background of Study
  • 1.3Problem Statement
  • 1.4Objectives of Study
  • 1.5Limitations of Study
  • 1.6Scope of Study
  • 1.7Significance of Study
  • 1.8Structure of the Research
  • 1.9Definition of Terms

Chapter TWO

LITERATURE REVIEW

  • 2.1Overview of Air Conditioning Systems
  • 2.2History of Air Conditioning Technology
  • 2.3Importance of Air Conditioning in Modern Society
  • 2.4Types of Air Conditioning Systems
  • 2.5Principles of Air Conditioning
  • 2.6Energy Efficiency in Air Conditioning
  • 2.7Common Faults in Air Conditioners
  • 2.8Maintenance and Repair of Air Conditioning Systems
  • 2.9Emerging Trends in Air Conditioning Technology
  • 2.10Environmental Impact of Air Conditioning Systems

Chapter THREE

SYSTEM DESIGN AND IMPLEMENTATION

  • 3.1Research Design
  • 3.2Sampling Methods
  • 3.3Data Collection Techniques
  • 3.4Data Analysis Procedures
  • 3.5Research Instruments
  • 3.6Ethical Considerations
  • 3.7Validity and Reliability
  • 3.8Limitations of the Methodology

Chapter FOUR

SYSTEM TESTING AND EVALUATION

  • 4.1Overview of Findings
  • 4.2Analysis of Data
  • 4.3Comparison of Results with Hypotheses
  • 4.4Discussion of Key Findings
  • 4.5Implications of Findings
  • 4.6Recommendations for Practice
  • 4.7Suggestions for Further Research
  • 4.8Conclusion of Findings

Chapter FIVE

SUMMARY, CONCLUSION AND RECOMMENDATIONS

  • 5.1Summary of Research
  • 5.2Conclusion
  • 5.3Contribution to Knowledge
  • 5.4Practical Implications
  • 5.5Recommendations for Future Studies

Project Abstract

<p>In the mechanical Engineering department of institute of management and technology there and many machines but not all in are good shape or form.<br><br>This may be due to inadequate maintenance, which is evident in the breakdown of air conditioner. In the case of machine maintenance, the quality and effusiveness of material were well noted. Also not left behind was the cost of maintenance which was minimized and yet getting to a highly successful repairs too.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In so long, during the repairs and rehabilitation of a faulty air conditioner appropriate tools, cost and quality of material were well considered.#<br></p>

Project Overview

<p>1.1 &nbsp; LITERATURE REVIEW<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Air conditioning is a process whereby heat received from a low temperature region is transferred to a higher temperature region. Then a negative net work is being done in the system. Air conditioning system has four basic components which are the compressor, condenser, metering device or thrilling valve and an evaporator. When any of these component is faulty or damaged it will cause the air condition system not to function well or not functioning at all.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place the faulty air conditioner was rehabilitated as a project by a group of students in the department of mechanical engineering 2004/2005 session.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Before working in the air conditioner by the group in the year 2005 the following fault were dictated.<br><br>1. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; It has low pumping that is the compressor not pumping any gas (refrigerant) in the system.<br><br>2. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors of the fan and compressor are bad.<br><br>3. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier was not able to filter the gas pumped by the compressor as result of blockage by impurities.<br><br>4. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The whole system was dirty, this is because the air conditioner have been dumped for a very long time.<br><br>The compressor is the heart of all air conditioning system. It pumps the refrigerant to the whole system.<br><br>The metering device or the expansion device meters a given quality of refrigerant required for each unit.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In this case most of these essential components of the air conditioner which seems to be very delicate, need not be handled carelessly, when it developed any fault and again, it should not be handled by non-exports in the field of air conditioning and refrigeration.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The last group that handled the project are classified as non-exports in the field of air conditioning. We say this because an air conditioning system that has the problems outlined above needs not be repaired as they had done without replacing some of the components with a brand new spare parts and the normal size that is the size of the machine air conditioner<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; For instance a compressor that has low pumping action, we verified that the compressor which supposed to b e two horse power (2hp) compressor. This under sized compressor has low pumping action, 6to the air conditioning set. Because the capillaries for the two horse power compressor for the bigger than that of 1.5 horse power air conditioning set.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Again the volume of air conditioning gas being pumped was too negligible to bring about the desired cooling.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors which was bad that is not good at all.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier which was blocked up by impurities was changed and replaced with a new one. As a result, its caused by poor cycling of refrigerant through. The copper capillary of the air conditioner which we repaired by replacing the drier with a new one. Through we can still be in a good condition.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; A repaired and rehabilitated equipment is supposed to be sound both internally and externally. The people who worked in the air conditioner before, were unable to spray the air conditioner which has many scratches as a result of their work.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Sincerely speaking and other criteria that contributed immensely to the braked own of the air conditioner was poor maintenance.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Plant maintenance is the upkeep of plant safe working state. Plant maintenance is divided in to planned preventive and breakdown maintenance were sub-divided.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Thus this report encomprises, urges the series of job done to arrive at a meaningful randy to breakdown problem.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Considering space, volume and relevance we will limit our write up (thesis) to the direct and practiced work of all the air conditioner.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place we used the basic procedure in tracing a fault like diecking of leakage with soap solution was done, flushing of the condenser which revealed the fault of the drier (filter) was done using vacuum pump. The compressor was tasted, there was no fault only that the size was 1.5 horse power (hp) and they have opened the compressor before and welded it which is not advisable to do.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The general dean up of all dust compacted parts was done particularly without any problems following by the changing of the plug which supply electricity to the system.<br><br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The sequence of operation and fools used during the repair is recorded in ascending order over leaf.<br><br>Purchase Detail<br>Hello, we’re glad you stopped by, you can download the complete project materials to this project with Abstract, Chapters 1 – 5, References and Appendix (Questionaire, Charts, etc) for N5000 ($15) only,<br>Please call 08111770269 or +2348059541956 to place an order or use the whatsapp button below to chat us up.<br>Bank details are stated below.<br><br>Bank: UBA<br>Account No: 1021412898<br>Account Name: Starnet Innovations Limited<br></p>

Blazingprojects Mobile App

📚 Over 50,000 Project Materials
📱 100% Offline: No internet needed
📝 Over 98 Departments
🔍 Software coding and Machine construction
🎓 Postgraduate/Undergraduate Research works
📥 Instant Whatsapp/Email Delivery

Blazingprojects App

Related Research

Mechanical engineeri. 3 min read

Design and Optimization of a Solar-Powered Autonomous Cooling System for Agricultura...

What This Project Is About This project focuses on creating a cooling system that runs independently using solar power. It aims to help keep stored agricultural...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Design and Analysis of a Solar-Powered Hybrid Electric Vehicle...

What This Project Is About This project focuses on designing and analyzing a vehicle that uses both solar power and electric energy to work. It looks at how to ...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Design and Development of an Automated Solar Tracking System for Enhanced Photovolta...

What This Project Is About This project focuses on creating a system that automatically points solar panels towards the sun as it moves across the sky. The goal...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Design and Optimization of a Solar-Powered Autonomous Agricultural Robot...

This project focuses on designing and improving a robot that can help farmers grow crops more easily and efficiently. The robot will be powered by solar energy,...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Design and Optimization of a Solar-Powered Autonomous Robotic Excavator...

This project is about creating a robotic excavator that runs on solar energy and can operate without a human controlling it directly. An excavator is a machine ...

BP
Blazingprojects
Read more →
Mechanical engineeri. 3 min read

Design and Optimization of a Solar-Powered Mechanical Ventilation System for Sustain...

This project is about designing a new kind of ventilation system for buildings that uses sunlight to power itself. Ventilation systems help keep indoor air fres...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Design and Development of an Autonomous Robotic Arm for Industrial Applications...

The project on &quot;Design and Development of an Autonomous Robotic Arm for Industrial Applications&quot; focuses on creating a cutting-edge robotic arm that c...

BP
Blazingprojects
Read more →
Mechanical engineeri. 3 min read

Design and analysis of a solar-powered desalination system....

The project titled &quot;Design and Analysis of a Solar-Powered Desalination System&quot; focuses on developing a sustainable solution to address the global wat...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Design and analysis of a solar-powered desalination system for remote communities....

The project &quot;Design and Analysis of a Solar-Powered Desalination System for Remote Communities&quot; aims to address the pressing need for sustainable acce...

BP
Blazingprojects
Read more →
WhatsApp Click here to chat with us