Rectification and repair of a faulty air conditioner in the mechanical engineering department at the institute of management and technology (i.m.t) enugu.

 

Table Of Contents


  • <p> </p><p>Title page</p><p>Letter of transmittal</p><p>Approval page</p><p>Dedication</p><p>Acknowledgement</p><p>Abstract</p><p>Table Of Content</p><p>

Chapter ONE

INTRODUCTION

  • </p><p>
  • 1.0&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Introduction</p><p>
  • 1.1&nbsp; &nbsp; literature review</p><p>

Chapter TWO

LITERATURE REVIEW

  • </p><p>
  • 2.0&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Analysis of the air conditioning cycle</p><p>
  • 2.1&nbsp; &nbsp; air conditioning maintenance</p><p>
  • 2.2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Preparation for repairs</p><p>
  • 2.3&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Fault detection and repairs</p><p>
  • 2.4&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Precaution taken</p><p>
  • 2.5&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The principles of operation of an air conditioner</p><p>
  • 2.6&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Component of air conditioner</p><p>
  • 2.7&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Air condition application</p><p>
  • 2.8&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Sequence of operation</p><p>
  • 2.9&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Cost analysis</p><p>

Chapter THREE

SYSTEM DESIGN AND IMPLEMENTATION

  • </p><p>
  • 3.1&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Conclusion</p><p>
  • 3.2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Recommendation</p><p>Reference</p> <br><p></p>

Project Abstract

<p> </p><p>In the mechanical Engineering department of institute of management and technology there and many machines but not all in are good shape or form.</p><p>This may be due to inadequate maintenance, which is evident in the breakdown of air conditioner. In the case of machine maintenance, the quality and effusiveness of material were well noted. Also not left behind was the cost of maintenance which was minimized and yet getting to a highly successful repairs too.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In so long, during the repairs and rehabilitation of a faulty air conditioner appropriate tools, cost and quality of material were well considered.</p> <br><p></p>

Project Overview

<p> </p><div><p>1.0 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; INTR9ODUCTION</p><p>1.1 &nbsp; &nbsp; LITERATURE REVIEW</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Air conditioning is a process whereby heat received from a low temperature region is transferred to a higher temperature region. Then a negative net work is being done in the system. Air conditioning system has four basic components which are the compressor, condenser, metering device or thrilling valve and an evaporator. When any of these component is faulty or damaged it will cause the air condition system not to function well or not functioning at all.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place the faulty air conditioner was rehabilitated as a project by a group of students in the department of mechanical engineering 2004/2005 session.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Before working in the air conditioner by the group in the year 2005 the following fault were dictated.</p><p>1. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; It has low pumping that is the compressor not pumping any gas (refrigerant) in the system.</p><p>2. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors of the fan and compressor are bad.</p><p>3. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier was not able to filter the gas pumped by the compressor as result of blockage by impurities.</p><p>4. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The whole system was dirty, this is because the air conditioner have been dumped for a very long time.</p><p>The compressor is the heart of all air conditioning system. It pumps the refrigerant to the whole system.</p><p>The metering device or the expansion device meters a given quality of refrigerant required for each unit.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In this case most of these essential components of the air conditioner which seems to be very delicate, need not be handled carelessly, when it developed any fault and again, it should not be handled by non-exports in the field of air conditioning and refrigeration.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The last group that handled the project are classified as non-exports in the field of air conditioning. We say this because an air conditioning system that has the problems outlined above needs not be repaired as they had done without replacing some of the components with a brand new spare parts and the normal size that is the size of the machine air conditioner</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; For instance a compressor that has low pumping action, we verified that the compressor which supposed to b e two horse power (2hp) compressor. This under sized compressor has low pumping action, 6to the air conditioning set. Because the capillaries for the two horse power compressor for the bigger than that of 1.5 horse power air conditioning set.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Again the volume of air conditioning gas being pumped was too negligible to bring about the desired cooling.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors which was bad that is not good at all.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier which was blocked up by impurities was changed and replaced with a new one. As a result, its caused by poor cycling of refrigerant through. The copper capillary of the air conditioner which we repaired by replacing the drier with a new one. Through we can still be in a good condition.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; A repaired and rehabilitated equipment is supposed to be sound both internally and externally. The people who worked in the air conditioner before, were unable to spray the air conditioner which has many scratches as a result of their work.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Sincerely speaking and other criteria that contributed immensely to the braked own of the air conditioner was poor maintenance.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Plant maintenance is the upkeep of plant safe working state. Plant maintenance is divided in to planned preventive and breakdown maintenance were sub-divided.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Thus this report encomprises, urges the series of job done to arrive at a meaningful randy to breakdown problem.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Considering space, volume and relevance we will limit our write up (thesis) to the direct and practiced work of all the air conditioner.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place we used the basic procedure in tracing a fault like diecking of leakage with soap solution was done, flushing of the condenser which revealed the fault of the drier (filter) was done using vacuum pump. The compressor was tasted, there was no fault only that the size was 1.5 horse power (hp) and they have opened the compressor before and welded it which is not advisable to do.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The general dean up of all dust compacted parts was done particularly without any problems following by the changing of the plug which supply electricity to the system.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The sequence of operation and fools used during the repair is recorded in ascending order over leaf.</p><p></p></div><h3></h3><br> <br><p></p>

Blazingprojects Mobile App

πŸ“š Over 50,000 Project Materials
πŸ“± 100% Offline: No internet needed
πŸ“ Over 98 Departments
πŸ” Software coding and Machine construction
πŸŽ“ Postgraduate/Undergraduate Research works
πŸ“₯ Instant Whatsapp/Email Delivery

Blazingprojects App

Related Research

Mechanical engineeri. 2 min read

Design and optimization of a passive vibration isolation system for high-precision C...

What This Project Is About A straightforward look at how to reduce unwanted vibrations in precision CNC machines using specially designed mounts made from metam...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Smart adaptive HVAC ducting system using shape memory alloy actuators for energy opt...

What This Project Is About The project looks at how to automatically adjust how air moves through a building’s ventilation ducts to save energy. It uses shape...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Design and optimization of a coupled electro-hydraulic actuation system for autonomo...

What This Project Is About A straightforward study of how to use a combination of electric motors and hydraulic components to control robotic grippers. The proj...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Design and optimization of a passive cooling system for high-power electric motors u...

What This Project Is About A plain-language overview of how a quiet, efficient cooling system can protect high-power electric motors by using layers of special ...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

- Design and feasibility study of a solar-assisted heat pump for domestic water heat...

What This Project Is About This project looks at several innovative energy and engineering ideas, each aiming to combine practicality with efficiency. It covers...

BP
Blazingprojects
Read more →
Mechanical engineeri. 4 min read

Development of an autonomous, energy-efficient solar-assisted cooling system for agr...

What This Project Is About A straightforward exploration of a cooling system for greenhouses that uses solar power and special materials to keep temperatures st...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Design and optimization of a modular autonomous micro-robotic gripper for delicate o...

What This Project Is About A straightforward, hands-on project about designing a small, modular gripper that can be controlled by a computer to pick up and rele...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Development of a lightweight, high-strength composite lattice structure for automoti...

What This Project Is About A straightforward, hands-on look at using lightweight, strong lattice structures made from composites to improve car crash energy abs...

BP
Blazingprojects
Read more →
Mechanical engineeri. 2 min read

Design and optimization of a passive cooling system for electric vehicle battery pac...

What This Project Is About A plain-language overview of the topic and what the project investigates. The Problem It Addresses What problem or gap this project ...

BP
Blazingprojects
Read more →
WhatsApp Click here to chat with us