Home / Chemistry / Head loses in horizontal and vertical orificemeter: a comparative analysis with application of statistical method

Head loses in horizontal and vertical orificemeter: a comparative analysis with application of statistical method

 

Table Of Contents


Project Abstract

Abstract
Orificemeters are commonly used in industrial applications to measure the flow rate of fluids. This study focuses on comparing the head losses in horizontal and vertical orificemeters through experimental analysis and statistical methods. The objective is to provide insights into the impact of orificemeter orientation on head losses, which is crucial for optimizing the design and operation of flow measurement systems. Experimental tests were conducted using both horizontal and vertical orificemeters with varying flow rates. The pressure differentials and flow rates were measured, and head losses were calculated for each orientation. The results indicated that the head losses in horizontal orificemeters were higher compared to vertical orificemeters for the same flow rates. This difference can be attributed to the flow patterns and turbulence generated in different orientations. Statistical analysis was applied to the experimental data to quantify the significance of the differences in head losses between horizontal and vertical orificemeters. The analysis revealed that the orientation of the orificemeter had a statistically significant effect on head losses. This finding emphasizes the importance of considering the orientation factor in the design and operation of flow measurement systems to minimize head losses and improve measurement accuracy. The results of this study have practical implications for industries relying on orificemeters for flow measurement. By understanding the impact of orificemeter orientation on head losses, engineers and operators can make informed decisions to optimize the performance of their flow measurement systems. This research contributes to the existing knowledge by providing a comparative analysis of head losses in horizontal and vertical orificemeters and demonstrating the application of statistical methods in evaluating the significance of the findings. In conclusion, this study highlights the importance of considering the orientation of orificemeters in industrial applications to minimize head losses and improve measurement accuracy. The experimental analysis and statistical methods employed in this research provide valuable insights for engineers and operators seeking to optimize the performance of flow measurement systems. Further research could explore additional factors influencing head losses in orificemeters and evaluate their combined effects on measurement accuracy.

Project Overview

INTRODUCTION
1.1. Background of the study
Fluid mechanics deals with the study of all fluids under static and dynamic situations. Fluid mechanics is a branch of continuous mechanics which deals with a relationship between forces, motions, and statical conditions in a continuous material. This study area deals with many and diversified problems such as surface tension, fluid statics, flow in enclose bodies, or flow round bodies (solid or otherwise), flow stability, etc. In fact, almost any action a person is doing involves some kind of a fluid mechanics problem. Researchers distinguish between orderly flow and chaotic flow as the laminar flow and the turbulent flow. The fluid mechanics can also be distinguished between a single phase flow and multiphase flow (flow made more than one phase or single distinguishable material).
Fluid flow in circular and noncircular pipes is commonly encountered in practice. The hot and cold water that we use in our homes is pumped through pipes. Water in a city is distributed by extensive piping networks. Oil and natural gas are transported hundreds of miles by large pipelines. Blood is carried throughout our bodies by veins. The cooling water in an engine is transported by hoses to the pipes in the radiator where it is cooled as it flows. Thermal energy in a hydraulic space heating system is transferred to the circulating water in the boiler, and then it is transported to
12
the desired locations in pipes. Fluid flow is classified as external and internal, depending on whether the fluid is forced to flow over a surface or in a conduit. Internal and external flows exhibit very different characteristics. In this chapter we consider internal flow where the conduit is completely filled with the fluid, and flow is driven primarily by a pressure difference. This should not be confused with open-channel flow where the conduit is partially filled by the fluid and thus the flow is partially bounded by solid surfaces, as in an irrigation ditch, and flow is driven by gravity alone. We then discuss the characteristics of flow inside pipes and introduce the pressure drop correlations associated with it for both laminar and turbulent flows. Finally, we present the minor losses and determine the pressure drop and pumping power requirements for piping systems. Pipes 611
14–5Liquid or gas flow through pipes or ducts is commonly used in heating and cooling applications, and fluid distribution networks. The fluid in such applications is usually forced to flow by a fan or pump through a flow section. We pay particular attention to friction, which is directly related to the pressure drop and head loss during flow through pipes and ducts. The pressure drop is then used to determine the pumping power requirement. A typical piping system
involves pipes of different diameters connected to each other by various fittings or elbows to direct the fluid, valves to control the flow rate, and pumps to pressurize the fluid. The terms pipe, duct, and conduit are usually used interchangeably for flow sections. In general, flow sections of circular cross section are referred to as
13
pipes (especially when the fluid is a liquid), and flow sections of noncircular cross section as ducts (especially when the fluid is a gas). Small-diameter pipes are usually referred to as tubes. Given this uncertainty, we will use more descriptive phrases (such as a circular pipe or a rectangular duct) whenever necessary to avoid any misunderstandings. You have probably noticed that most fluids, especially liquids, are transported in circular pipes. This is because pipes with a circular cross section can withstand large pressure differences between the inside and the outside without undergoing significant distortion. Noncircular pipes are usually used in applications such as the heating and cooling systems of buildings where the pressure difference is relatively small, the manufacturing and installation costs are lower, and the available space is limited for duct work. Although the theory of fluid flow is reasonably well understood, theoretical solutions are obtained only for a few simple cases such as fully developed laminar flow in a circular pipe. Therefore, we must rely on experimental results and empirical relations for most fluid-flow problems rather than closed form analytical solutions. Noting that the experimental results are obtained under carefully controlled laboratory conditions, and that no two systems are exactly alike, we must not be so naive as to view the results obtained as ―exact.‖ The fluid velocity in a pipe changes from zero at the surface because of the no-slip condition to a maximum at the pipe center. In fluid flow, it is convenient to work with an average or mean velocity _m, which remains constant in incompressible flow when the cross-sectional area of the pipe is
14
constant. The mean velocity in heating and cooling applications may change somewhat because of changes in density with temperature. But, in practice, we evaluate the fluid properties at some average temperature and treat them as constants. The convenience of working with constant properties usually more than justifies the slight loss in accuracy.
Also, the friction between the fluid layers in a pipe does cause a slight rise in fluid temperature as a result of the mechanical energy being converted to sensible thermal energy. But this temperature rise due to fictional heating is usually too small to warrant any consideration in calculations and thus is disregarded. For example, in the absence of any heat transfer, no noticeable difference can
be detected between the inlet and exit temperatures of water flowing in a pipe. The primary consequence of friction in fluid flow is pressure drop, and thus any significant temperature change in the fluid is due to heat transfer.PDF

Blazingprojects Mobile App

📚 Over 50,000 Project Materials
📱 100% Offline: No internet needed
📝 Over 98 Departments
🔍 Software coding and Machine construction
🎓 Postgraduate/Undergraduate Research works
📥 Instant Whatsapp/Email Delivery

Blazingprojects App

Related Research

Chemistry. 4 min read

Development of Novel Catalysts for Green Chemistry Applications...

The project on "Development of Novel Catalysts for Green Chemistry Applications" aims to address the pressing need for more sustainable and environmen...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Synthesis and Characterization of Novel Metal-Organic Frameworks for Gas Separation ...

The project titled "Synthesis and Characterization of Novel Metal-Organic Frameworks for Gas Separation Applications" focuses on the development and a...

BP
Blazingprojects
Read more →
Chemistry. 4 min read

Development of Novel Catalysts for Sustainable Organic Synthesis Reactions...

The project "Development of Novel Catalysts for Sustainable Organic Synthesis Reactions" focuses on addressing the growing need for environmentally fr...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Development of Novel Catalysts for Green Energy Production...

The project on "Development of Novel Catalysts for Green Energy Production" aims to address the growing need for sustainable and efficient energy sour...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Synthesis and Characterization of Metal-Organic Frameworks for Gas Separation Applic...

The project on "Synthesis and Characterization of Metal-Organic Frameworks for Gas Separation Applications" focuses on the development and evaluation ...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Investigating the effects of pH on enzyme activity in catalase....

The project titled "Investigating the effects of pH on enzyme activity in catalase" aims to explore the impact of varying pH levels on the activity of...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Synthesis and Characterization of Novel Organic Polymers for Drug Delivery Applicati...

The project on "Synthesis and Characterization of Novel Organic Polymers for Drug Delivery Applications" aims to explore the development of innovative...

BP
Blazingprojects
Read more →
Chemistry. 4 min read

Investigation of the effects of different catalysts on the rate of a chemical reacti...

The project aims to investigate and analyze the impact of various catalysts on the rate of a chemical reaction. Catalysts play a crucial role in accelerating or...

BP
Blazingprojects
Read more →
Chemistry. 4 min read

Development of Novel Catalysts for Green Chemistry Applications...

The project titled "Development of Novel Catalysts for Green Chemistry Applications" focuses on the synthesis and application of innovative catalysts ...

BP
Blazingprojects
Read more →
WhatsApp Click here to chat with us